reflow-oven-control-sw/doc/source/firmware/safety/startup-tests.rst

24 lines
720 B
ReStructuredText
Raw Normal View History

.. _safety_startup_tests:
Startup Tests
=============
The following tests will be performed after each reset / power cycle of the controller.
Internal Memory Test
--------------------
Directly after startup and after setting up the system clocks, the controller performs memory checks on the internal SRAM and the core coupled memory.
RAM checking is performed by testing the following sequences:
- Alternating 0x55AA55AA / 0xAA55AA55 pattern
- Alternating 0xAA55AA55 / 0x55AA55AA pattern
- 0xFFFFFFFF constant value
- 0x00000000 constant value
The following functions implement the RAM checking:
.. doxygenfunction:: startup_test_perform_ccm_ram_check
.. doxygenfunction:: startup_test_perform_system_ram_check