Documentation: Fix docu of overtemp flag

This commit is contained in:
Mario Hüttel 2021-03-18 23:21:17 +01:00
parent 857838f293
commit 13e7cbfd81
2 changed files with 6 additions and 2 deletions

View File

@ -136,7 +136,11 @@ ERR_FLAG_OVERTEMP
--------------------------- ---------------------------
``ERR_FLAG_OVERTEMP`` is set if the :ref:`pt1000_processing` detects an overtemperature. ``ERR_FLAG_OVERTEMP`` is set if the :ref:`pt1000_processing` detects an overtemperature.
The default limit is ``260 degrees Celsius``. However, it is possible to configure the limit and permanenty store it in the EEPROM since hardware version v1.3. The default limit is set to:
.. doxygendefine:: SAFETY_DEFAULT_OVERTEMP_LIMIT_DEGC
However, it is possible to configure the limit and permanenty store it in the EEPROM since hardware version v1.3.
========== ============= ============= =========== ========== ============= ============= ===========

View File

@ -130,7 +130,7 @@ enum analog_value_monitor {
#define SAFETY_EXT_WATCHDOG_PIN (12) #define SAFETY_EXT_WATCHDOG_PIN (12)
/** /**
* @brief Default Limit of the overtemperature detection * @brief Default Limit of the overtemperature detection in degrees celsius
*/ */
#define SAFETY_DEFAULT_OVERTEMP_LIMIT_DEGC (260.0f) #define SAFETY_DEFAULT_OVERTEMP_LIMIT_DEGC (260.0f)