Documentation: Fix docu of overtemp flag
This commit is contained in:
parent
857838f293
commit
13e7cbfd81
@ -136,7 +136,11 @@ ERR_FLAG_OVERTEMP
|
||||
---------------------------
|
||||
|
||||
``ERR_FLAG_OVERTEMP`` is set if the :ref:`pt1000_processing` detects an overtemperature.
|
||||
The default limit is ``260 degrees Celsius``. However, it is possible to configure the limit and permanenty store it in the EEPROM since hardware version v1.3.
|
||||
The default limit is set to:
|
||||
|
||||
.. doxygendefine:: SAFETY_DEFAULT_OVERTEMP_LIMIT_DEGC
|
||||
|
||||
However, it is possible to configure the limit and permanenty store it in the EEPROM since hardware version v1.3.
|
||||
|
||||
|
||||
========== ============= ============= ===========
|
||||
|
@ -130,7 +130,7 @@ enum analog_value_monitor {
|
||||
#define SAFETY_EXT_WATCHDOG_PIN (12)
|
||||
|
||||
/**
|
||||
* @brief Default Limit of the overtemperature detection
|
||||
* @brief Default Limit of the overtemperature detection in degrees celsius
|
||||
*/
|
||||
#define SAFETY_DEFAULT_OVERTEMP_LIMIT_DEGC (260.0f)
|
||||
|
||||
|
Loading…