Issue #5: Write documentation for error flags and their handling
This commit is contained in:
parent
dcd1fa9605
commit
324e6d506d
9
doc/source/firmware/error-handling.rst
Normal file
9
doc/source/firmware/error-handling.rst
Normal file
@ -0,0 +1,9 @@
|
||||
.. _safety_handling:
|
||||
|
||||
Error Handling
|
||||
==============
|
||||
|
||||
.. _safety_panic:
|
||||
|
||||
Panic Mode
|
||||
----------
|
@ -7,23 +7,63 @@ The safety flags are represented in software by the following enums
|
||||
|
||||
.. doxygenenum:: safety_flag
|
||||
|
||||
The safety flags can be temporarily or permanent. Some temporary flags are reset automatically, once the error condition disappears. Others have to be explicitly cleared.
|
||||
|
||||
.. _safety_flags_adc_overflow:
|
||||
|
||||
ERR_FLAG_MEAS_ADC_OVERFLOW
|
||||
--------------------------
|
||||
|
||||
``ERR_FLAG_MEAS_ADC_OVERFLOW`` is triggered in case of an overflow in the signal path of the measurement ADC. This should never happen unless there is a bug in the software.
|
||||
|
||||
========== ============= ============= ===========
|
||||
persistent self-clearing Stops PID Panic Mode
|
||||
========== ============= ============= ===========
|
||||
yes no yes no
|
||||
========== ============= ============= ===========
|
||||
|
||||
.. _safety_flags_adc_off:
|
||||
|
||||
ERR_FLAG_MEAS_ADC_OFF
|
||||
---------------------
|
||||
|
||||
``ERR_FLAG_MEAS_ADC_OFF`` signals that the measurment ADC for the PT1000 sensor is deactivated. This flag is automatically cleared by the firmware
|
||||
once the ADC is started.
|
||||
|
||||
========== ============= ============= ===========
|
||||
persistent self-clearing Stops PID Panic Mode
|
||||
========== ============= ============= ===========
|
||||
no yes yes no
|
||||
========== ============= ============= ===========
|
||||
|
||||
|
||||
.. _safety_flags_adc_watchdog:
|
||||
|
||||
ERR_FLAG_MEAS_ADC_WATCHDOG
|
||||
--------------------------
|
||||
|
||||
``ERR_FLAG_MEAS_ADC_WATCHDOG`` is used as a wire break detection mechanism. This flag is set when the PT1000 measurement ADC detects an invalid resistance measurement.
|
||||
|
||||
.. seealso:: :ref:`ADC Watchdog<firmware_meas_adc_watchdog>`
|
||||
|
||||
========== ============= ============= ===========
|
||||
persistent self-clearing Stops PID Panic Mode
|
||||
========== ============= ============= ===========
|
||||
no no yes no
|
||||
========== ============= ============= ===========
|
||||
|
||||
|
||||
.. _safety_flags_adc_unstable:
|
||||
|
||||
ERR_FLAG_MEAS_ADC_UNSTABLE
|
||||
--------------------------
|
||||
|
||||
``ERR_FLAG_MEAS_ADC_UNSTABLE`` is set after startup of the PT1000 measuremnt or after reconfiguring the filter settings.
|
||||
|
||||
.. seealso:: :ref:`firmware_meas_adc_filter`
|
||||
|
||||
========== ============= ============= ===========
|
||||
persistent self-clearing Stops PID Panic Mode
|
||||
========== ============= ============= ===========
|
||||
no yes no no
|
||||
========== ============= ============= ===========
|
@ -92,6 +92,8 @@ The equation is implemented in
|
||||
|
||||
and applied during the `Exponential Moving Average Filter`_.
|
||||
|
||||
.. _firmware_meas_adc_filter:
|
||||
|
||||
Exponential Moving Average Filter
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
@ -158,7 +160,7 @@ The default values, if no calibration is loaded / executed, are:
|
||||
============== =========
|
||||
:math:`\sigma` :math:`O`
|
||||
============== =========
|
||||
0 1
|
||||
0 0
|
||||
============== =========
|
||||
|
||||
Get Calibration Corrected Value
|
||||
|
@ -6,7 +6,14 @@ Safety Controller
|
||||
The safety controller is the software component that monitors the overall condition of the reflow controller,
|
||||
and stops the output driver in case of an error.
|
||||
|
||||
Severe error flags, like a drifting reference voltage, stop the PID controller and force the output to zero.
|
||||
The controller stays in a usable state. After the errors have been cleared, normal operation may continue.
|
||||
|
||||
On the other hand, fatal errors like an over-temperature error, or memory problem, lead to the activation of the :ref:`safety_panic`,
|
||||
which forces the output zero, but does not allow any more interaction.
|
||||
|
||||
.. toctree::
|
||||
:maxdepth: 2
|
||||
|
||||
flags
|
||||
error-handling
|
||||
|
Loading…
Reference in New Issue