From 6ebd74cb31cb673029205d1cc6af32a7c8524611 Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Mario=20H=C3=BCttel?= Date: Sun, 4 Apr 2021 19:35:32 +0200 Subject: [PATCH] Safety Bug: Add meas ADC timing flag to output of the pt1000 read function so it becomes invalid in this case. --- stm-firmware/adc-meas.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/stm-firmware/adc-meas.c b/stm-firmware/adc-meas.c index c598e42..10cf853 100644 --- a/stm-firmware/adc-meas.c +++ b/stm-firmware/adc-meas.c @@ -232,7 +232,7 @@ int adc_pt1000_get_current_resistance(float *resistance) *resistance = adc_pt1000_apply_calibration(pt1000_res_raw_lf); if (safety_controller_get_flags_by_mask(ERR_FLAG_MEAS_ADC_OFF | ERR_FLAG_MEAS_ADC_OVERFLOW | - ERR_FLAG_MEAS_ADC_WATCHDOG)) { + ERR_FLAG_MEAS_ADC_WATCHDOG | ERR_FLAG_TIMING_MEAS_ADC)) { ret_val = -100; goto return_value; }