@ -74,3 +75,5 @@ breathe_default_members = ('members', 'undoc-members')
blockdiag_html_image_format = 'SVG'
blockdiag_latex_image_format = 'PDF'
todo_include_todos = True

View File

@ -1,7 +1,7 @@
.. _api:
Firmware Code Documentation
===========================
Important Code APIs
===================
.. toctree::
:maxdepth: 2

View File

@ -1,11 +1,11 @@
.. _firmware:
Reflow Controller Firmware Internals
====================================
Reflow Controller Firmware
==========================
This chapter describes the internals of the reflow controller's firmware.
This chapter describes the reflow controller's firmware.
This is in most cases not intended to be a code documentation but an overview over the functional
mechanisms and the behavior.
mechanisms and the behavior. For a detailed code documentation see the doxygen output.
.. toctree::
:maxdepth: 2

View File

@ -24,7 +24,7 @@ The following block diagram shows the processing chain of the temperature signal
ADC2RES [label= "Val -> Ohm", description="`Conversion from ADC value to resistance in Ohms <ADC Value to Ohm_>`_"]
MAVG [label="MAVG Filter", description="`Exponential Moving Average Filter`_"];
RAW_HF [label="HF", shape = endpoint, description="High Frequency raw value reading"];
PT1000 [label = "LF", shape = endpoint, description="Low Frequency PT1000 resistance value"]
PT1000 [label = "LF", shape = endpoint, description="Low Frequency PT1000 resistance value (see: `MAVG Filter <Exponential Moving Average Filter_>`_)"]
RAW_STREAM [label = "Stream", shape = endpoint, description="Raw value streaming"];
ADC -> WATCHDOG;
@ -106,3 +106,86 @@ and can be changed in code using
After initial startup and after each change of the filter constant, the filter will set the :ref:`safety_flags_adc_unstable` flag for a defined sample count of:
.. doxygendefine:: ADC_FILTER_STARTUP_CYCLES
The moving average filter's output signal is the Low Frequency (LF) PT1000 resistance signal used for internal PT1000 measurements.
Reading and Converting the PT1000 Value
---------------------------------------
Calibration
~~~~~~~~~~~
The functions
.. doxygenfunction:: adc_pt1000_set_resistance_calibration
:outline:
and
.. doxygenfunction:: adc_pt1000_get_resistance_calibration
:outline:
are used to set the reistance calibration internally. For a guide on how to calibrate the deivce, see the usage page.
.. todo:: Add link here
The calibration is calculated the following way:
.. blockdiag::
:desctable:
blockdiag {
orientation = portrait;
LF [label="LF", shape=beginpoint, description="Low Frequency PT1000 Value"];
SENS [label="Sens", description="Sensitivity Correction :math:`\sigma`"];
OFFSET [label="Offset", description="Offset Correction :math:`O`"];
OUT [shape=endpoint, description="Corrected Value"];
LF -> SENS -> OFFSET -> OUT
}
The final calibrated PT1000 resistance is calculated as:
.. math::
R_{PT1000_{corr}} = R_{PT1000_{LF}} \cdot (1 + \sigma) + O
The default values, if no calibration is loaded / executed, are:
============== =========
:math:`\sigma` :math:`O`
============== =========
0 1
============== =========
Get Calibration Corrected Value
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
The PT1000 value is available through the following function.
If a calibration is set, it is applied.
.. doxygenfunction:: adc_pt1000_get_current_resistance
Converting the Value
~~~~~~~~~~~~~~~~~~~~
The valid range for conversion is between
.. doxygendefine:: TEMP_CONVERSION_MIN_RES
:outline:
and
.. doxygendefine:: TEMP_CONVERSION_MAX_RES
:outline:
By default, the valid range is:
.. math::
1000~\Omega \le R_{PT1000} \le 2200~\Omega
.. doxygenfunction:: temp_converter_convert_resistance_to_temp
The cvonversion function is based on a lookup table with linear interpolation between the data points.
The lookuptable is stored as a header file and can, if necessary, be recreated using the `create-temp-lookup-table.py` script.

View File

@ -138,15 +138,13 @@ void adc_pt1000_set_resistance_calibration(float offset, float sensitivity_devia
void adc_pt1000_get_resistance_calibration(float *offset, float *sensitivity_deviation, bool *active);
/**
* @brief Get the current reistance value
* @brief Get the current resistance value
*
* If the reistance calibration is enabled, this function applies the calculations of the raw resistance reading and
* If the resistance calibration is enabled, this function applies the calculations of the raw resistance reading and
* returns the corrected value.
*
* If an ADC error is set, the status is negative. The status is 2 during the first measurements with a given filter setting. Technically, the resistance value is
* correct but the filter is not stable yet.
* Use adc_pt1000_check_error to check the error and reinitialize the ADC.
*
*
* @param[out] resistance Resistance output in Ohms
* @return Status