Renamed clock-enable manager to rcc manager and improve some header files with doxygen comments
This commit is contained in:
@@ -29,23 +29,54 @@
|
||||
#include <stdint.h>
|
||||
#include <stdbool.h>
|
||||
|
||||
enum safety_adc_meas_channel {SAFETY_ADC_MEAS_VREF, SAFETY_ADC_MEAS_TEMP};
|
||||
/**
|
||||
* @brief The safety ADC's measure channel
|
||||
*/
|
||||
enum safety_adc_meas_channel {
|
||||
SAFETY_ADC_MEAS_VREF, /**< @brief Internal reference voltage @note This will not output the internal reference voltage but the recalculated external voltage! */
|
||||
SAFETY_ADC_MEAS_TEMP, /**< @brief Internal temperature sensor */
|
||||
};
|
||||
|
||||
/**
|
||||
* @brief Initialize safety ADC. Only call this function once!
|
||||
*/
|
||||
void safety_adc_init(void);
|
||||
|
||||
/**
|
||||
* @brief safety_adc_deinit Deactivate safety ADC
|
||||
* @warning For completeness. Do not call! the safety ADC is a vital component. It's malfunction will trigger a critical safety flag.
|
||||
*/
|
||||
void safety_adc_deinit(void);
|
||||
|
||||
/**
|
||||
* @brief safety_adc_trigger_meas
|
||||
*/
|
||||
void safety_adc_trigger_meas(void);
|
||||
|
||||
/**
|
||||
* @brief Poll ADC result.
|
||||
* @param results adc results
|
||||
* @return 1 if measurement successful, 0 if not ready, -1 if ADC aborted or not started
|
||||
*/
|
||||
int safety_adc_poll_result(void);
|
||||
|
||||
/**
|
||||
* @brief Get the sampled signal values of the safety ADC.
|
||||
*
|
||||
* Use #safety_adc_poll_result to poll for a finished conversion of the safety ADC.
|
||||
* After that, it is safe to use the output values until a new conversion is triggered using #safety_adc_trigger_meas
|
||||
*
|
||||
* @warning This function return a constant buffer, that is directly written on by the DMA! Check #safety_adc_poll_result to prevent race conditions.
|
||||
* @return Array of raw ADC readings with lenght of #SAFETY_ADC_NUM_OF_CHANNELS
|
||||
*/
|
||||
const uint16_t *safety_adc_get_values(void);
|
||||
|
||||
/**
|
||||
* @brief Convert a safety ADC raw value to an actual signal value
|
||||
* @param channel Measurment channel to convert voltage for
|
||||
* @param analog_value Raw value of the ADC to convert
|
||||
* @warning Double check @ref safety_adc_meas_channel to make sure you understand the output of this function correctly.
|
||||
* @return
|
||||
*/
|
||||
float safety_adc_convert_channel(enum safety_adc_meas_channel channel, uint16_t analog_value);
|
||||
|
||||
#endif /* __SAFETY_ADC_H__ */
|
||||
|
@@ -18,10 +18,21 @@
|
||||
* If not, see <http://www.gnu.org/licenses/>.
|
||||
*/
|
||||
|
||||
/**
|
||||
* @file safety-config.h
|
||||
* @brief Safety Controller Configuration.
|
||||
* @warning MAKE SURE XOU UNDERSTAND WHAT YOU ARE DOING IN HERE
|
||||
*/
|
||||
|
||||
#ifndef __SAFETY_CONFIG_H__
|
||||
#define __SAFETY_CONFIG_H__
|
||||
|
||||
|
||||
/**
|
||||
* @brief Enum type representing safety flags.
|
||||
*
|
||||
* The enum type is binary or'able to allow combining
|
||||
* multiple safety flags.
|
||||
*/
|
||||
enum safety_flag {
|
||||
ERR_FLAG_NO_FLAG = 0,
|
||||
ERR_FLAG_MEAS_ADC_OFF = (1<<0),
|
||||
@@ -43,6 +54,12 @@ enum safety_flag {
|
||||
ERR_FLAG_SAFETY_TAB_CORRUPT = (1<<16),
|
||||
};
|
||||
|
||||
/**
|
||||
* @brief Enum Type representing timing monitors.
|
||||
*
|
||||
* The enum type is binary or'able to allow combining
|
||||
* multiple safety flags.
|
||||
*/
|
||||
enum timing_monitor {
|
||||
ERR_TIMING_PID = (1<<0),
|
||||
ERR_TIMING_MEAS_ADC = (1<<1),
|
||||
@@ -50,6 +67,12 @@ enum timing_monitor {
|
||||
ERR_TIMING_MAIN_LOOP = (1<<3),
|
||||
};
|
||||
|
||||
/**
|
||||
* @brief Enum Type representing analog value monitors.
|
||||
*
|
||||
* The enum type is binary or'able to allow combining
|
||||
* multiple safety flags.
|
||||
*/
|
||||
enum analog_value_monitor {
|
||||
ERR_AMON_VREF = (1<<0),
|
||||
ERR_AMON_UC_TEMP = (1<<1),
|
||||
@@ -97,10 +120,13 @@ enum analog_value_monitor {
|
||||
|
||||
|
||||
/**
|
||||
* @brief Key used to lock the safety flags from external ack'ing
|
||||
* @brief Key used to lock the safety flags coming from the measurment ADC from external ack'ing
|
||||
*/
|
||||
#define MEAS_ADC_SAFETY_FLAG_KEY 0xe554dac3UL
|
||||
|
||||
/**
|
||||
* @brief Safety ADC trigger interval
|
||||
*/
|
||||
#define SAFETY_CONTROLLER_ADC_DELAY_MS 250
|
||||
|
||||
#define SAFETY_CONFIG_DEFAULT_PERSIST ERR_FLAG_PERSIST_ENTRY(ERR_FLAG_MEAS_ADC_OFF, false), \
|
||||
|
Reference in New Issue