/* Reflow Oven Controller
|
|
*
|
|
* Copyright (C) 2020 Mario Hüttel <mario.huettel@gmx.net>
|
|
*
|
|
* This file is part of the Reflow Oven Controller Project.
|
|
*
|
|
* The reflow oven controller is free software: you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
* published by the Free Software Foundation.
|
|
*
|
|
* The Reflow Oven Control Firmware is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with the reflow oven controller project.
|
|
* If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
/**
|
|
* @addtogroup safety-adc
|
|
* @{
|
|
*/
|
|
|
|
#ifndef __SAFETY_ADC_H__
|
|
#define __SAFETY_ADC_H__
|
|
|
|
#include <stdint.h>
|
|
#include <stdbool.h>
|
|
|
|
/**
|
|
* @brief The safety ADC's measure channel
|
|
*/
|
|
enum safety_adc_meas_channel {
|
|
SAFETY_ADC_MEAS_VREF, /**< @brief Internal reference voltage @note This will not output the internal reference voltage but the recalculated external voltage! */
|
|
SAFETY_ADC_MEAS_TEMP, /**< @brief Internal temperature sensor */
|
|
SAFETY_ADC_MEAS_SUPPLY, /**< @brief Supply voltage */
|
|
};
|
|
|
|
/**
|
|
* @brief Initialize safety ADC. Only call this function once!
|
|
*/
|
|
void safety_adc_init(void);
|
|
|
|
/**
|
|
* @brief safety_adc_deinit Deactivate safety ADC
|
|
* @warning For completeness. Do not call! the safety ADC is a vital component. It's malfunction will trigger a critical safety flag.
|
|
*/
|
|
void safety_adc_deinit(void);
|
|
|
|
/**
|
|
* @brief safety_adc_trigger_meas
|
|
*/
|
|
void safety_adc_trigger_meas(void);
|
|
|
|
/**
|
|
* @brief Poll ADC result.
|
|
* @return 1 if measurement successful, 0 if not ready, -1 if ADC aborted or not started
|
|
*/
|
|
int safety_adc_poll_result(void);
|
|
|
|
/**
|
|
* @brief Get the sampled signal values of the safety ADC.
|
|
*
|
|
* Use #safety_adc_poll_result to poll for a finished conversion of the safety ADC.
|
|
* After that, it is safe to use the output values until a new conversion is triggered using #safety_adc_trigger_meas
|
|
*
|
|
* @warning This function return a constant buffer, that is directly written on by the DMA! Check #safety_adc_poll_result to prevent race conditions.
|
|
* @return Array of raw ADC readings with lenght of #SAFETY_ADC_NUM_OF_CHANNELS
|
|
*/
|
|
const uint16_t *safety_adc_get_values(void);
|
|
|
|
/**
|
|
* @brief Convert a safety ADC raw value to an actual signal value
|
|
* @param channel Measurment channel to convert voltage for
|
|
* @param analog_value Raw value of the ADC to convert
|
|
* @warning Double check @ref safety_adc_meas_channel to make sure you understand the output of this function correctly.
|
|
* @return
|
|
*/
|
|
float safety_adc_convert_channel(enum safety_adc_meas_channel channel, uint16_t analog_value);
|
|
|
|
#endif /* __SAFETY_ADC_H__ */
|
|
|
|
/** @} */
|