Issue #21: Change calibration apply function
This commit is contained in:
		
							
								
								
									
										1
									
								
								stm-firmware/.gitignore
									
									
									
									
										vendored
									
									
								
							
							
						
						
									
										1
									
								
								stm-firmware/.gitignore
									
									
									
									
										vendored
									
									
								
							@@ -14,3 +14,4 @@ reflow-controller.includes
 | 
			
		||||
*.includes
 | 
			
		||||
*.config
 | 
			
		||||
*.files
 | 
			
		||||
*.user.*
 | 
			
		||||
 
 | 
			
		||||
@@ -216,7 +216,7 @@ void adc_pt1000_get_resistance_calibration(float *offset, float *sensitivity_dev
 | 
			
		||||
static inline float adc_pt1000_apply_calibration(float raw_resistance)
 | 
			
		||||
{
 | 
			
		||||
	if (calibration_active)
 | 
			
		||||
		return pt1000_res_raw_lf * (1.0f + pt1000_sens_dev) + pt1000_offset;
 | 
			
		||||
        return (raw_resistance - pt1000_offset) * (1.0f + pt1000_sens_dev);
 | 
			
		||||
	else
 | 
			
		||||
		return raw_resistance;
 | 
			
		||||
 | 
			
		||||
 
 | 
			
		||||
		Reference in New Issue
	