Add preliminary safety ADC which measures the Controller temperature and checks the reference voltage against the STM's internal reference voltage
This commit is contained in:
@@ -0,0 +1,31 @@
|
||||
/* Reflow Oven Controller
|
||||
*
|
||||
* Copyright (C) 2020 Mario Hüttel <mario.huettel@gmx.net>
|
||||
*
|
||||
* This file is part of the Reflow Oven Controller Project.
|
||||
*
|
||||
* The reflow oven controller is free software: you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License version 2 as
|
||||
* published by the Free Software Foundation.
|
||||
*
|
||||
* The Reflow Oven Control Firmware is distributed in the hope that it will be useful,
|
||||
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||||
* GNU General Public License for more details.
|
||||
*
|
||||
* You should have received a copy of the GNU General Public License
|
||||
* along with the reflow oven controller project.
|
||||
* If not, see <http://www.gnu.org/licenses/>.
|
||||
*/
|
||||
|
||||
#ifndef __SAFETY_ADC_HWCFG_H__
|
||||
#define __SAFETY_ADC_HWCFG_H__
|
||||
|
||||
#include <stm32/stm32f4xx.h>
|
||||
|
||||
#define SAFETY_ADC_ADC_PERIPHERAL ADC1
|
||||
#define SAFETY_ADC_ADC_RCC_MASK RCC_APB2ENR_ADC1EN
|
||||
#define TEMP_CHANNEL_NUM (16)
|
||||
#define INT_REF_CHANNEL_NUM (17)
|
||||
|
||||
#endif /* __SAFETY_ADC_HWCFG_H__ */
|